Indopoxy 990CT is High Solid High Build Coal Tar polyamide cured coal tar epoxy mastic with excellent resistance to sea water, crude oil, various soil chemicals and chemical fumes. It is a Self priming coating on most surfaces.
Indopoxy 990CT is recommended for use as a long-life protective coating on steel and concrete in severe corrosive environment. Most recommended on submerged surfaces, crude oil and slop tanks, ballast tanks, splash zones, sewage systems, etc. It has excellent resistance to chemical attack encountered on both steel and concrete including buried pipes.
Colour
Black
Finish
Semi Glossy
Soild by Volume
90 ± 3%
Supply Weight (Kg/ Ltr)
1.55±0.05
Flash Point
23° C
Dry Heat Resistance
Intermittent : 150°C, Continuous : 90°C
Shelf Life
12 months
Recommended film thickness per coat
Dry Film Thickness
200-300μ in single coat
Wet Film Thickness
225-335μ in single coat
Therotical Coverage Rate
4.50 sq.mt / lit at recommended DFT of 200μ
All surfaces to be coated should be clean, absolutely dry and oil or moisture free before painting application. Oil and grease should be removed by solvent cleaning.
Repair Cases : Corroded areas should be power tool cleaned to St3 or blast cleaned to Sa2 or better. Existing system should be dry and free from loose paint, salt, grease and other contaminants prior to overcoating.
New steel : Abrasive blasting to Sa 2½ (ISO 8501-1:2007). 990CT is also designed to apply on manually cleaned steel surface. However all damage of shopprimer and contamination from storage and fabrication should be thoroughly cleaned prior to final painting.
Maintenance : : Remove oil and grease etc. thoroughly with suitable detergent. Remove salts and other contaminants by high pressure fresh water cleaning. Clean damaged areas thoroughly by power tool cleaning to St 3 (ISO 8501-1:2007) (minor areas) or by abrasive blasting to min. Sa 2, preferably to Sa 2½ (ISO 8501-1:2007). Improved surface preparation will improve the performance of the product.
Concrete : The surface should be perfectly dry and clean before applying 990CT. Grease, Oil etc should be removed by solvent. If needed roughen the surface by acid etching. New concrete shoule be cured for minimum 2 months. Slip agent and other possible contaminants should be cleaned by detergent washing followed by high pressure hosing with fresh water. Remove scum layer and loose matter to a hard, rough and uniform surface, preferably by abrasive blasting, or any other mechanical treatment or acid etching
Application Method
Airless Spray, Brush/ Roller (Only Touch up)
Mixing Ratio
4 Part (Base) : 1 Part (Hardener)
Pot Life
Four Hours at 30°C
Thinner and Cleaner
Indopoxy Epoxy Thinner (IK.1501)
Airless Nozzle Orifice
0.53 - 0.78mm
Nozzle Pressure
211 kg/cm² or 3000 psi